Vision 260™ – 5.4″ STN LCD PLC & HMI

PLC with built-in graphic LCD display (Expandable to 316)

Features:

  • CCFL fluorescent lamp LED
  • Negative Blue STN Graphic LCD
  • Function Keys
  • Up to 256 IO

Description

As well as a comprehensive range of touchscreen PLCs Unitronics also offer touchscreen technology combined with traditional hard keys for those who prefer the tactile feedback of a real key.

A 240 x 64 pixel 5.4″ blue STN LCD screen with 33 user labelled keys.

Specifications:

  • 12/24VDC
  • 260×64 5.4″ Negative blue STN LCD
  • Keypad with no I/O included
  • RS232/RS485

VisiLogic

i4 Automation Visilogic Software for Unitronics

VisiLogic is an easy to use and intuitive programming software that is included with this product.

VisiLogic is a powerful software package that allows the Vision™ series of integrated PLC & HMI to be programmed easily and quickly.  The software has a familiar intuitive feel and incorporates many advanced features such as discrete program routines, function blocks, data tables, data logging, trending and alarm handling.  All of the standard maths functions are available and complex formula can be developed without the need to have a degree in computer science!

The integrated intuitive function blocks really make the Vision™ series the powerful devices that they are.  There are many pre-set function blocks available performing a wide variety of advanced tasks as easily as dropping & dragging an icon into your program and configuring a few parameters.

Subjects such as CAN Open networking, Modbus communications, pulse trains outputs and bespoke serial communication protocols all have function blocks available to make the programmers life less difficult.  To find out more detail about the range of function blocks available visit the VisiLogic software page HERE.

You can use VisiLogic and the associated software utilities to program, control, access and download data to and from the PLC remotely and directly.

Get more information about the VisiLogic programming software HERE

Manuals

V260 Manual Description Install Manual Technical Manual
V260-16-B20B 12/24VDC, 260×64 5.4″ Negative blue STN LCD, Keypad with no I/O included, RS232/RS485 PDF Link PDF Link

Snap-In IO

Often referred to as “Snap In Modules”, only  1 snap in module per display. Additional IO can be added using the DIN rail mounted modules (see IO+ options)
Inputs Outputs
Part No. Digital (Isolated) HSC/ Shaft Encoder Analogue Temp (MEAS) Transistor (Isolated) PWM/HSO Relay Analogue Manuals
V200-18-E1B 16 pnp/npn 2 10kHz 32-bit 3 0-10 V, 0-20mA, 4-20mA 10-bit None 4 pnp/npn 2 pnp 0.5kHz npn 50kHz 10 None PDF Link
V200-18-E2B 16 pnp/npn 2 10kHz 32-bit 2 0-10 V, 0-20mA, 4-20mA 10-bit None 4 pnp/npn 2 pnp 0.5kHz npn 50kHz 10 2 0-10 V,0-20mA,4-20mA 12-bit PDF Link
V200-18-E3XB 18 pnp/npn 2 10kHz 32-bit 4 (Isolated) Thermocouple, PT100, 0-10V, 0-20mA, 4-20mA 14-bit 2 pnp/npn 2 pnp 0.5kHz npn 50kHz 15 4 (Isolated) 0-10 V, 4-20mA 12-bit PDF Link
V200-18-E4XB 18 pnp/npn 2 10kHz 32-bit 4 (Isolated) Thermocouple, PT100, 0-10V, 0-20mA, 4-20mA 14-bit 15 pnp 2 2 pnp 0.5kHz npn 50kHz None 4 (Isolated) 0-10 V, 4-20mA 12-bit PDF Link
V200-18-E5B 18 pnp/npn 2 10kHz 32-bit 3 0-10 V,0-20mA, 4-20mA None 15 pnp 2 2 pnp 0.5kHz npn 50kHz None None PDF Link
V200-18-E6B 18 pnp/npn 2 10kHz 32-bit 2 Thermocouple, PT100, 0-10V, 0-20mA, 4-20mA 14-bit 2 pnp/npn 2 pnp 0.5kHz npn 50kHz 15 2 (Isolated) 0-10 V, 4-20mA 12-bit PDF Link
V200-18-E46B 18 pnp/npn 2 10kHz 32-bit 6 0-10 V,0-20mA,4-20mA 14-bit None 2 pnp/npn 2 pnp 0.5kHz npn 100kHz 15 2 (Isolated) 0-10 V, 4-20mA 12-bit PDF Link
V200-18-E62B 30 pnp/npn 2 50kHz 32-bit 2 0-10 V,0-20mA,4-20mA 10-bit None 28 pnp 2 2 pnp 0.5kHz npn 100kHz None None PDF Link

Communications

Part Number Description Manual
V200-19-RS4 1 RS485 port (V570, V560, V1040, V1210 etc) PDF Link
V200-19-RS4-X 1 RS232/RS485 (Isolated) (V570, V560, V1040, V1210 etc) PDF Link
V200-19-ET2 1 Ethernet port (V570, V560, V1040, V1210 etc) PDF Link
CANbus 1 CANbus port built in, see product manual

IO Adapter & Cables

The screens can have addition or only DIN rail mounted IO using the interfaces below and some of the additional IO modules shown (IO+) and / or the On board IO.
For DIN rail mounted IO you will need an interface unit, first.
Inputs Outputs
Part No. Digital (Isolated) HSC/ Shaft Encoder Analogue Temp Measurement Weight Measurement Transistor (Isolated) PWM/HSO Relay Analogue Manuals
EX-D16A3-RO8 16 pnp/npn 2    30kHz 16/32-bit 3   0-20mA, 4-20mA 10-bit None None None None 8 None PDF LinkPDF Link
EX-D16A3-TO16 16 pnp/npn 1    30kHz 16/32-bit 3   0-20mA, 4-20mA 10-bit None None 15 pnp 1 pnp/npn 1 pnp 0.5kHz None None PDF LinkPDF Link
EX90-DI8-RO8 8 1 None None None None None 8 None PDF Link
EXF-RC15 9 pnp/npn 3   200kHz 32-bit None None None 4 npn 4(Up to 3 PTO) 2 None PDF LinkPDF Link
EX-A2X (was EX-A1) *Needed for IO expansion
Local I/O adaptor allows the connection of up to 8 I/O expansion modules per PLC.
1m cable includedOnly 1 EX-A2X module per PLC (If more I/O modules are required the EX-RC1 can be used)
PDF Link
EX-RC1 *Needed for IO expansion
Remote I/O adaptor module via CANbus, multiple EX-RC1 adaptors may be connected to each PLC with up to 8 I/O expansion modules per adaptor.Multiple EX-RC1 modules can be used per PLC.
PDF Link
Expansion adapter cables*
EXL-CAB050 Expansion cable (0.5m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB100 Expansion cable (1m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB200 Expansion cable (2m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB295 Expansion cable (2.95m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB400 Expansion cable (4m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB500 Expansion cable (5m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB600 Expansion cable (6m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB1000 Expansion cable (10m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB1200 Expansion cable (12m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB2000 Expansion cable (20m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
EXL-CAB3000 Expansion cable (30m) For use with EX-A2X and Expansion I/O modules beginning EX-D…..
If you need help configuring your Inputs and Outputs please feel free to contact us.
We also offer software support.
IO = Inputs and Outputs

Digital IO

The screens can be expanded via DIN rail mounted IO using the interfaces below together with the on board/ Snap-in IO and ethernet IO expansion options. 
Digital Inputs and Outputs (12V DC available on request)
Inputs Outputs
Part No. Digital (Isolated) HSC/ Shaft Encoder Analogue Temp Measurement
Weight Measurement Transistor (Isolated) PWM/HSO Relay Analogue Manuals
IO-DI8-TO8  8 pnp/npn 1        5kHz 16-bit None None None 8 pnp None None None PDF Link
IO-DI8-RO4   8 pnp/npn 1        5kHz 16-bit None None None None None 4 None PDF Link
IO-DI8-RO8  8 pnp/npn 1        5kHz 16-bit None None None None None 8 None PDF Link
EX90-DI8-RO8 8 pnp 1        5kHz 16-bit None None None None None 8 None PDF Link
IO-DI16  16 pnp/npn 1        5kHz 16-bit None None None None None None None PDF Link
IO-TO16  None None None None None 16 pnp None None None PDF Link
IO-RO8 None None None None None None None 8 None PDF Link
IO-RO16 None None None None None None None 16 None PDF Link
IO-DI8ACH 8 AC None None None None None None None None PDF Link
IO-D16A3-RO16  16 pnp/npn 2    30kHz 16/32-bit 3

0-20mA, 4-20mA 10-bit

None None None None 16 None

PDF Link

PDF Link

IO-D16A3-TO16  16 pnp/npn 1    30kHz 16/32-bit 3

0-20mA, 4-20mA 10-bit

None None 15 pnp, 1 pnp/npn 1 pnp 0.5kHz npn 50kHz None None

PDF Link

PDF Link

EX-D16A3-RO8  16 pnp/npn 2    30kHz 16/32-bit 3

0-20mA, 4-20mA 10-bit

None None None None 8 None

PDF Link

PDF Link

EX-D16A3-TO16  16 pnp/npn 1    30kHz 16/32-bit 3

0-20mA, 4-20mA 10-bit

None None 15 pnp 1 pnp/npn 1 pnp 0.5kHz npn 50kHz None None

PDF Link

PDF Link

If you need help configuring your Inputs and Outputs please feel free to contact us.
We also offer software support.
IO = Inputs and Outputs

Analogue IO

The screens can have addition or only DIN rail mounted IO using the interfaces below and some of the additional IO modules shown (IO+) and / or the On board IO.
Analogue, Thermocouple, PT100, PT1000 and Load cell units
Inputs Outputs
Part No. Digital (Isolated) HSC/ Shaft Encoder Analogue Temp Measurement Weight Measurement Transistor (Isolated) PWM/HSO Relay Analogue Manuals
IO-AI4-AO2     None None 4

0-10V, 0-20mA, 4-20mA 12-bit

None None None None None 2 ±10V 12-bit+sign, 0-20mA, 4-20mA 12-bit PDF Link
IO-PT400  None None None 4

PT100/NI100/NI120

None None None None None PDF Link
IO-PT4K  None None None 4

PT1000/NI1000

None None None None None PDF Link
IO-AO6X  None None None None None None None None 6 (Isolated) 0-10V,    0-20mA, 4-20mA 12-bit PDF Link
IO-LC1 1 pnp None None None 1 Loadcell / Strain gauge 2 pnp None None None PDF Link
IO-LC3 1 pnp None None None 3 Loadcell / Strain gauge 2 pnp None None None PDF Link
IO-ATC8 None None 8

Thermocouple, 0-10V,           0-20mA, 4-20mA 14-bit

None None None None None PDF Link
IO-AI8 None None 8

0-10V, 0-20mA, 4-20mA 14-bit

None None None None None None PDF Link
IO-D16A3-RO16  16 pnp/npn 2 30kHz 16/32-bit 3

0-20mA, 4-20mA 10-bit

None None None None 16 None PDF Link

PDF Link

IO-D16A3-TO16  16 pnp/npn 1 30kHz 16/32-bit 3

0-20mA, 4-20mA 10-bit

None None 15 pnp, 1 pnp/npn 1 pnp 0.5kHz npn 50kHz None None PDF Link

PDF Link

EX-D16A3-RO8  16 pnp/npn 2 30kHz 16/32-bit 3

0-20mA, 4-20mA 10-bit

None None None None 8 None PDF LinkPDF Link
EX-D16A3-TO16  16 pnp/npn 1 30kHz 16/32-bit 3

0-20mA, 4-20mA 10-bit

None None 15 pnp, 1 pnp/npn 1 pnp 0.5kHz None None PDF Link

PDF Link

If you need help configuring your Inputs and Outputs please feel free to contact us.
We also offer software support.
IO = Inputs and Outputs

24V DC Power Supplies

Part Number PU Data Sheet
722752 Regulated, 18 W Power Supply PDF Link
722753 Regulated, 30 W Power Supply PDF Link
722754 Regulated, 60 W Power Supply PDF Link
722758 Regulated, 120 W Power Supply PDF Link
722759 Regulated, 240 W Power Supply PDF Link
722800 Regulated, 480 W, 3-Phase Power Supply PDF Link

Modem & Routers

Part No. Description Install Manual Quick Start Manual User Guide
GSM-KIT-16J KIT,MODEM GPRS,CINTERION ,BGS2T PDF Link N/A N/A
GSM-KIT-17J-3G KIT,MODEM GPRS,CINTERION ,EHS6T PDF Link N/A N/A
UniStream Cloud Routers
UCR-ST-B5-EU Unitronics Router B5 Europe PDF Link PDF Link PDF Link
UCR-ST-B8-EU Unitronics Router B8 Europe PDF Link PDF Link PDF Link
UCR-ST-B5-AT Unitronics Router B5 USA AT&T PDF Link PDF Link PDF Link
UCR-ST-B8-AT Unitronics Router B8 USA AT&T PDF Link PDF Link PDF Link
UCR-ST-B5-VE Unitronics Router B5 USA Verizon PDF Link PDF Link PDF Link
UCR-ST-B8-VE Unitronics Router B8 USA Verizon PDF Link PDF Link PDF Link
UCR-ST-B5-SA Unitronics Router B5 Rest of World PDF Link PDF Link PDF Link
UCR-ST-B8-SA Unitronics Router B8 Rest of World PDF Link PDF Link PDF Link
UCR-OP-B5-DIN UCR B5B8 DIN RAIL KIT N/A
Legacy i4A Routers
RUT230i4A Teltonika RUT230 HSPA+ 3G Router with 2 x Ethernet ports and Wi-Fi- supplied with DIN rail mounting kit + magnetic indoor aerial. Discontinued
RUT240i4A Teltonika RUT240 HSPA+ 4G Router with 2 x Ethernet ports and Wi-Fi- supplied with DIN rail mounting kit + magnetic indoor aerial. Discontinued
BAC Net routers
GW-BAC1 BACnet to Modbus Gateway PDF Link
GW-KNX1 BACnet to Modbus Gateway PDF Link
ULC-BNET101 BACnet IP Server Unistream License N/A

Technical Drawings