Unitronics
|
![]() |
|||
Expand your system with local or remote I/O expansion modules. Vision
series supports local & remote, M90/M91 supports local only. Exceptions apply, call 01480 395256 |
||||
Unitronics' PLCs can support IO either directly on board, via local expansion units or via a CANbus network (not M90/M91). The following IO modules can be used as either local or remote IO, they all DIN rail mount and will need an expansion adaptor to connect to the PLC. Expansion adaptors come in three different variants and you need choose only one of them for each PLC. The EX-A1 or EX-A2X adaptor is a stand alone expansion adaptor which connects to the PLC via a CAT5 cable and to a further eight IO modules via ribbon cable. In all three cases these cables are included with the modules where required. The EX-RC1 adaptor is a stand alone network adaptor that connects to up to eight IO modules via ribbon cables but then connects to the master PLC on a CANbus network. The CANbus cable is user supplied. (Allows these Din rail IO units to be connected to UniStream PLC over CANbus) The EX-XL IO modules which are expansion units with an integral adaptor and connect to the PLC via a CAT5 cable then up to seven more IO modules via ribbon cable. If required the PLC may be expanded via both local and remote IO (M90/91 via local only) up to the IO limit of the particular PLC model, see user guides. Only one local expansion adaptor may be used with up to eight extra modules (seven if the integral EX-XL module is used). Further IO expansion, up to the IO limit, must then be made via CANbus. |
I/O Expansion Module Adaptors | |||||
Part Number | Description | Installation Manual | Technical Specification | ||
EX-A2X |
12/24VDC local I/O adaptor allows the connection of up to 8 I/O expansion modules per PLC. 1m cable included | ||||
EX-RC1 |
12/24VDC remote I/O adaptor module via CANbus, multiple adaptors may be connected to each PLC with up to 8 I/O expansion modules per adaptor. | ||||
EXF-RC15 |
24VDC high speed remote I/O adaptor module via CANbus, multiple adaptors may be connected
to each PLC. Consists of three high speed counter inputs (max 200kHz), four high speed outputs (max 200kHz)
and two relay outputs. |
- |
|||
24VDC I/O Expansion Modules | |||||
Part Number | Description | Installation Manual | Technical Specification | ||
IO-DI8-TO8 |
8 Digital Inputs / 8 Transistor Outputs, 24VDC | ||||
IO-DI8-RO4 |
8 Digital Inputs / 4 Relay Outputs, 24VDC | ||||
IO-DI8-RO8 |
8 Digital Inputs / 8 Relay Outputs, 24VDC | ||||
IO-DI16 |
16 Digital Inputs, 24VDC | ||||
IO-RO8 |
8 Relay Outputs, 24VDC | ||||
IO-RO16 |
16 Relay Outputs, 24VDC | ||||
EX90-DI8-RO8 |
7 Digital Inputs / 1 Digital or high speed 5kHz input / 8 Relay Outputs,includes adaptor, 24VDC. When this adaptor is used no ther expansion modules can be connected. | ||||
12VDC I/O Expansion Module | |||||
Part Number | Description | Installation Manual | Technical Specification | ||
IO-DI8-TO8-L |
8 Digital Inputs / 8 Transistor Outputs, 12VDC | ||||
IO-DI8-RO4-L |
8 Digital Inputs / 4 Relay Outputs, 12VDC | ||||
IO-DI8-RO8-L |
8 Digital Inputs / 8 Relay Outputs, 12VDC | ||||
IO-DI16-L |
16 Digital Inputs, 12VDC | ||||
IO-RO8-L |
8 Relay Outputs, 12VDC | ||||
IO-RO16-L |
16 Relay Outputs, 12VDC | ||||
12/24VDC I/O Expansion Module | |||||
Part Number | Description | Installation Manual | Technical Specification | ||
IO-TO16 |
16 Transistor Outputs, 12/24VDC | ||||
110/220VAC I/O Expansion Module | |||||
Part Number | Description | Installation Manual | Technical Specification | ||
IO-DI8ACH |
8 110/220VAC Digital Inputs | ||||
Analogue & Temperature measurement modules | |||||
Part Number | Description | Installation Manual | Technical Specification | ||
IO-AI4-AO2 |
4 Analogue Inputs / 2 Analogue Outputs | ||||
IO-AO6X |
6 Isolated Analogue Outputs | ||||
IO-PT400 |
PT100 / NI100 / NI120 Inputs | ||||
IO-PT4K |
4 PT1000 / NI1000 Inputs | ||||
IO-ATC8 |
8 Thermocouple/Analogue Inputs | ||||
IO-AI8 |
8 Analogue Inputs | ||||
Weight or Strain measurement modules | |||||
Part Number | Description | Installation Manual | Technical Specification | ||
IO-LC1 |
1 Loadcell/Strain gauge Input, 1 Digital Input / 1 Setpoint Digital Output | ||||
IO-LC3 |
3 Loadcell/Strain gauge Inputs, 1 Digital Input / 1 Setpoint Digital Output | ||||
24VDC XL expansion module (digital + analogue) | |||||
Part Number | Description | Installation Manual | Technical Specification | ||
IO-D16A3-RO16 |
16 Digital Inputs / 3 Analogue Inputs / 16 Relay Outputs, 24VDC | ||||
IO-D16A3-TO16 |
16 Digital Inputs / 3 Analogue Inputs / 16 Transistor Outputs, 24VDC | ||||
EX-D16A3-RO8 |
16 Digital Inputs / 3 Analogue Inputs / 8 Relay Outputs, includes IO adapter, 24VDC | ||||
EX-D16A3-TO16 |
16 Digital Inputs / 3 Analogue Inputs / 16 Transistor Outputs, includes IO adapter, 24VDC | ||||
Superceded models | |||||
Part Number | Description | Installation Manual | Technical Specification | ||
EX-A1 |
12/24VDC local I/O adaptor allows the connection of up to 8 I/O expansion modules per PLC. 1m cable included |