BACKGROUND
i4Automation

   01480 395256
web@i4Automation.co.uk

   01480 395256
web@i4Automation.co.uk


Please NOTE: First 4 results are ads

Unitronics
I/O Expansion
Modules

V350 with remote I/O image

 

I/O expansion module comparison table

I/O module comparison

Expand your system with local or remote I/O expansion modules.  Vision series supports local & remote, M90/M91 supports local only.

Exceptions apply, call 01480 395256


Unitronics' PLCs can support IO either directly on board, via local expansion units or via a CANbus network (not M90/M91). The following IO modules can be used as either local or remote IO, they all DIN rail mount and will need an expansion adaptor to connect to the PLC.  Expansion adaptors come in three different variants and you need choose only one of them for each PLC.



The EX-A1 or EX-A2X adaptor is a stand alone expansion adaptor which connects to the PLC via a CAT5 cable and to a further eight IO modules via ribbon cable. In all three cases these cables are included with the modules where required.


The EX-RC1 adaptor is a stand alone network adaptor that connects to up to eight IO modules via ribbon cables but then connects to the master PLC on a CANbus network. The CANbus cable is user supplied. (Allows these Din rail IO units to be connected to UniStream PLC over CANbus)


The EX-XL IO modules which are expansion units with an integral adaptor and connect to the PLC via a CAT5 cable then up to seven more IO modules via ribbon cable.


If required the PLC may be expanded via both local and remote IO (M90/91 via local only) up to the IO limit of the particular PLC model, see user guides. Only one local expansion adaptor may be used with up to eight extra modules (seven if the integral EX-XL module is used). Further IO expansion, up to the IO limit, must then be made via CANbus.


I/O Expansion Module Adaptors
Part Number Description Installation Manual Technical Specification

EX-A2X

12/24VDC local I/O adaptor allows the connection of up to 8 I/O expansion modules per PLC. 1m cable included

EX-A2X installation manual

 

EX-RC1

12/24VDC remote I/O adaptor module via CANbus, multiple adaptors may be connected to each PLC with up to 8 I/O expansion modules per adaptor.

EX-RC1 installation manual

 

EXF-RC15

24VDC high speed remote I/O adaptor module via CANbus, multiple adaptors may be connected to each PLC. Consists of three high speed counter inputs (max 200kHz), four high speed outputs (max 200kHz) and two relay outputs.

-

EX-RC1 specifications manual

24VDC I/O Expansion Modules
Part Number Description Installation Manual Technical Specification

IO-DI8-TO8

8 Digital Inputs / 8 Transistor Outputs, 24VDC

IO-DI8-TO8 installation manual

 

IO-DI8-RO4

8 Digital Inputs / 4 Relay Outputs, 24VDC

IO-DI8-RO4 installation manual

 

IO-DI8-RO8

8 Digital Inputs / 8 Relay Outputs, 24VDC

IO-DI8-RO8 installation manual

 

IO-DI16

16 Digital Inputs, 24VDC

IO-DI16 installation manual

 

IO-RO8

8 Relay Outputs, 24VDC

IO-RO8 installation manual

 

IO-RO16

16 Relay Outputs, 24VDC

IO-RO16 installation manual

 

EX90-DI8-RO8

7 Digital Inputs / 1 Digital or high speed 5kHz input / 8 Relay Outputs,includes adaptor, 24VDC. When this adaptor is used no ther expansion modules can be connected.

EX90-DI8-RO8 installation manual

 
12VDC I/O Expansion Module
Part Number Description Installation Manual Technical Specification

IO-DI8-TO8-L

8 Digital Inputs / 8 Transistor Outputs, 12VDC

IO-DI8-TO8-L installation manual

 

IO-DI8-RO4-L

8 Digital Inputs / 4 Relay Outputs, 12VDC

IO-DI8-RO4-L installation manual

 

IO-DI8-RO8-L

8 Digital Inputs / 8 Relay Outputs, 12VDC

IO-DI8-RO8-L installation manual

 

IO-DI16-L

16 Digital Inputs, 12VDC

IO-DI16-L installation manual

 

IO-RO8-L

8 Relay Outputs, 12VDC

IO-RO8-L installation manual

 

IO-RO16-L

16 Relay Outputs, 12VDC

IO-RO16-L installation manual

 
12/24VDC I/O Expansion Module
Part Number Description Installation Manual Technical Specification

IO-TO16

16 Transistor Outputs, 12/24VDC

 IO-TO16 installation manual

 
110/220VAC I/O Expansion Module
Part Number Description Installation Manual Technical Specification

IO-DI8ACH

8 110/220VAC Digital Inputs

IO-DI8ACH installation manual

 
Analogue & Temperature measurement modules
Part Number Description Installation Manual Technical Specification

IO-AI4-AO2

4 Analogue Inputs / 2 Analogue Outputs

IO-AI4-AO2 installation manual

 

IO-AO6X

6 Isolated Analogue Outputs

 IO-AO6X installation manual

 

IO-PT400

PT100 / NI100 / NI120 Inputs

IO-PT400 installation manual

 

IO-PT4K

4 PT1000 / NI1000 Inputs

IO-PT4K installation manual

 

IO-ATC8

8 Thermocouple/Analogue Inputs

IO-ATC8 installation manual

 

IO-AI8

8 Analogue Inputs

IO-AI8 installation manual

 
Weight or Strain measurement modules
Part Number Description Installation Manual Technical Specification

IO-LC1

1 Loadcell/Strain gauge Input, 1 Digital Input / 1 Setpoint Digital Output

IO-LC1 installation manual

 

IO-LC3

3 Loadcell/Strain gauge Inputs, 1 Digital Input / 1 Setpoint Digital Output

IO-LC3 installation manual

 
24VDC XL expansion module (digital + analogue)
Part Number Description Installation Manual Technical Specification

IO-D16A3-RO16

16 Digital Inputs / 3 Analogue Inputs / 16 Relay Outputs, 24VDC

IO-D16A3-RO16 installation manual

IO-D16A3-RO16 specification manual

IO-D16A3-TO16

16 Digital Inputs / 3 Analogue Inputs / 16 Transistor Outputs, 24VDC

IO-D16A3-TO16 installation manual

IO-D16A3-TO16 specification manual

EX-D16A3-RO8

16 Digital Inputs / 3 Analogue Inputs / 8 Relay Outputs, includes IO adapter, 24VDC

EX-D16A3-RO8 installation manual

EX-D16A3-RO8 specification manual

EX-D16A3-TO16

16 Digital Inputs / 3 Analogue Inputs / 16 Transistor Outputs, includes IO adapter, 24VDC

EX-D16A3-TO16 installation manual

EX-D16A3-TO16 specification manual

Superceded models
Part Number Description Installation Manual Technical Specification

EX-A1

12/24VDC local I/O adaptor allows the connection of up to 8 I/O expansion modules per PLC. 1m cable included

EX-A1 installation manual